Hints from the Health Department. Leaflet from the archive of the Society of Medical Officers of Health. Credit: Wellcome Collection, London
[Report of the Medical Officer of Health for Tottenham]
This page requires JavaScript
Average Results of the Chemical and Bacteriological Examination of the Water Supplied to the Borough of Tottenham for the Year 1957
Milligrams per litre (Unless otherwise stated)
Description of the Sample | No, of Samples | Ammoniacal Nitrogen | Album inoid Nitrogen | Oxidised Nitrogen (Nitrate) | Chlorides as cl. | Oxygen abs. from Permanganate 4 hrs. at 27 C | Turbidity Units | Colour m. m brown 2ft. Tube Burgess' s Tintometer | Hardness (Total) | Hardness (Non carbonate) | pH. Value | Electrical Conductivity (gemmhos) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
New River water filtered at Hornsey works | 238 | 0.012 | 0.046 | 5.6 | 34 | 0.60 | 0.1 | 5 | 300 | 64 | 7.8 | 625 |
New River water filtered at Stoke New -ington works | 238 | 0.028 | 0.045 | 5.5 | 34 | 0.59 | 0.1 | 6 | 298 | 62 | 7.9 | 600 |
River Thames derived filtered water | 1882 | 0.027 | 0. 074 | 3.9 | 29 | 1.16 | 0.3 | 11 | 260 | 56 | 7.9 | 550 |
Description of sample | No. of Samples | Plate count (average per m. 1.) Colonies counted on agar after 20-24 hrs. at 37°C | Coliform Test Percentage of Samples negative in 100 m. 1. | ||
---|---|---|---|---|---|
Coliform | E. Coli | ||||
New River water filtered at Hornsey works | 256 | 9.4 | 99.61 | 100 | |
New River water filtered at Stoke Newington works | 256 | 11.2 | 100 | 100 | |
River Thames derived filtered water | 3438 | 6.4 | 99.33 | 99.91 |