Average Results of Analyses of Metropolitan Water Board Supply. (Parts per million). Water filtered and chlorinated at Hampton Works:

No. of Samples232
Ammoniacal Nitrogen0.011
Albuminoid Nitrogen0.083
Oxidised Nitrogen (Nitrate)3.9
Chlorides as CI.26
Oxygen abs. from Permanganate 4 hours at 27°C.1.05
Turbidity in terms of Silica0.3
Colour m.m. brown 2ft. tube Burgess's Tintometer13
Hardness Total261
Hardness (Non-Carbonate)67
pH Value7.8
Phosphate as PO4111 0.50
Silica as SIO110
Sulphates as SO449
Conductivity450
Bacteriological Results
Colony Count on agar at 37°C (20-24 hours)4.8
BACT. COLI TEST
Percentage of samples negative per 100 ml.100.0
Bact. Coli per 100 mlNil

Typical Analysis of South West S.W. Co. Supply

(Parts per million):

Chemical
AppearanceClear and Bright
TurbidityNil
OdourNil
Colour4
Free Carbon Dioxide9
Total Solids355
Alkalinity as Calcium Carbonate195
pH7.5
Electric Conductivity530
Chlorine present as Chloride27
Hardness: Total (Carbonate 195 Non-Carbonate 55)250
Nitrate Nitrogen3.2
Nitrite Nitrogenless than 0.01
Ammoniacal Nitrogen0.004
Albuminoid Nitrogen0.033
Oxygen Absorbed0.60
Residual Chlorineabsent
Metalsabsent