London's Pulse: Medical Officer of Health reports 1848-1972

View report page

Feltham 1954

[Report of the Medical Officer of Health for Feltham]

This page requires JavaScript

Average Results of Analyses of Metropolitan Water Board Supply. (Parts per million). Water filtered and chlorinated at Hampton Works:

No. of Samples225
Ammoniacal Nitrogen0.020
Albuminoid Nitrogen0.092
Oxidised Nitrogen (Nitrate)4.0
Chlorides as C1.26.4
Oxygen abs. from Permanganate 4 hours at 27°C.1.23
Turbidity in terms of Silica0.3
Colour m.m. brown 2 ft. tube Burgess's Tintometer14
Hardness Total271
Hardness (Non-Carbonate)72
pH Value7.9
Phosphate as P.O. 41110.65
Silica as SIO111
Magnesium5
Sulphate50
Conductivity475

Bacteriological Results
No. of Samples 963
Colony Count on agar at 37°C (20-24 hours) 5.6
BACT. COLI TEST
Percentage of samples negative per 100 ml 100.0
Bact. Coli per 100 ml. Nil

Typical Analysis of South West S.W. Co. Supply (Parts per 100,000):

Chemical

Total solids (dried at 120°C.)35.0
Combined chlorine (as C1.)2.7
equivalent to Sodium Chloride (NaCl)4.5
Nitric Nitrogen (Nitrates)0.40
Nitrous Nitrogen (Nitrites)Nil
Ammoniacal Nitrogen0.0006
Albuminoid Nitrogen0.0130
Oxygen absorbed in 4 hours at 27°C0.170
Lead or CopperNil
Temporary hardness (equivalent to CaC03)21.5
Permanent hardness (equivalent to CaC03)7.0
Total hardness (equivalent to CaC03)28.5

Bacteriological
Agar plate count, at 20-22°C. for three days=4 per ml.
Agar plate count, at 37°C. for two days=3 per ml.
Faecal coli not found in 100 ml.
Probable number of coliform bacilli = None per 100 ml.
Enterococci not found in 100 ml.
C1. welchii (spores) present in 25 ml.