Table: Concentration of Smoke and Sulphur Dioxide recorded by the Volumetric Method at the two stations in the Borough
Download table as:
text
HTML
CSV
XML
Concentration of Smoke and Sulphur Dioxide recorded by the Volumetric Method at the two stations in the Borough
Station Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec. SMOKE, (Milligrams per 100 cubic metres) Public Health Office, Town Hall Monthly average 29.0 25.0 17.0 12.0 7.0 4.0 3.0 6.0 7.0 14.0 18.0 28.0 Highest daily average 93.0 70.0 40.0 32.0 15 0 9.0 7.0 12.0 16 0 21.0 40.0 83.0 Shelter House, Treatment Centre. Monthly average 33.0 27.0 15.0 15.0 8.0 3.0 6.0 5.0 6.0 13.0 15.0 46.0 Highest daily average 102.0 65.0 30.0 42.0 18.0 8.0 18.0 12.0 14.0 29.0 43.0 181.0 SULPHUR DIOXIDE. (Parts per 100 million parts of air) Public Health Office, Town Hall. Monthly average 13.3 12.8 8.6 6.5 4.5 2.7 2.9 4.1 5.0 8.3 12.0 13.7 Highest daily average 35.6 23.2 20.1 15.3 14.3 9.5 10.8 7.3 9.7 14. 5 23.4 23.9 Shelter House, Treatment Centre. Monthly average 10.1 11.1 7.2 7.1 5.8 5.1 3.2 4.2 3.8 7.7 9.1 14.1 Highest daily average 34.9 25.4 15.1 15.7 14.4 12.4 9.5 10.8 6.8 14.2 17.9 31.7
![]()
match: ALTO ComposedBlock ..\26 February 2013\Folder 2\b18239407\Tables\b18239407_0049_045_037.xml