London's Pulse: Medical Officer of Health reports 1848-1972

View report page

Finsbury 1904

Report on the public health of Finsbury 1904 including annual report on factories and workshops

This page requires JavaScript

204
205

Continued from previous page...

Index Number.Nature of Premises.• Description of Room.N umber of Occupants and Space.Gas, Oil, or Electric Light, in use at time of test.Date, Time, and Position of Test.Volume of C02 per 10,000.# Means of Ventilation in in actual use at time of test.Remarks.
Position, Process, &c.Cubic Capacity, in feet.Height.Number present.Space per person.Date and Time.Where Sampled.Inside Room.Outside Air.
24Eel & Pie ShopUnderground kitchen2970 (approx.)11 ft.21440No gas12 noon, June 3rdRight-hand side centre103.5Large grating in front, grating at side, hoist and stairsSample taken in a position where the air was stagnant.
DittoDittoditto11 ft.21440DittoDittoFront left side83.5DittoSample from a more favourable position.
WORKSHOPS AND FACTORIES.
33Factory LaundryGround floor. Gas ironing, &c.approx. 1450012 ft.2558010 gas jets, 11 ironing machines, 12 box irons, gas heatedNoon, Dec. 15thEnd of room, under exhaust fan124.530-in. exhaust fan, stairs from basement, all windows shutThe exhaust fan was stopped for 10 minutes before the last sample was taken. The read- ing showed that the CO2 rose rapidly in the interval.
DittoDitto1450012 ft.25580DittoDittoBody of room104.5Ditto
DittoDitto1450012 ft.25580DittoDittoEnd of room, under exhaust fan204.5Fan stopped for ten minutes
34Linen Collar WorkshopGround floor. 50 machinists at work12180050 ft. (approx.)5621756 gas irons, 3 gas jets2 P.m., Dec. 15thBody of room164.5Two cowls in roof, 1 Tobin tube, 2 hooded stoves-/
DittoDitto121800ditto562175DittoDittoDitto104.5Two large trap doors in roof wide open, and 1 Tobin tube in addition to aboveThe second sample was taken after the trap doors in the roof and an additional Tobin tube had been left open for 10 minuies. The CO2 had fallen.
25Cork-sock ManufactorySecond floor13650Average 13 ft.13105011 gas jets alight gas stove beside fireplacel2.40 p.m., Dec. 12th, 1904Body of room, at breathing level315One window open about 4 inches, holes at bottom of skylightsGas jets alight for drying materials, heat from fire being insufficient. Tem perature high.
DittoDittoDittoDittoBody of room, 2 feet below breathing level295Ditto
26Feather WorkshopThird floor554411 ft.105546 gas jets aligt♦11.30 a.m., 12th, 1964Body of room485All windows shut, chimney partly blocked offPractically unventilated stuffy and oppressive.