Hints from the Health Department. Leaflet from the archive of the Society of Medical Officers of Health. Credit: Wellcome Collection, London
[Report of the Medical Officer of Health for Fulham]
This page requires JavaScript
The following notices were served in respect of dwelling houses during the year:—
| Intimation Notices. | Statutory Notices. | ||
|---|---|---|---|
| Number served. | Number complied with up to 31st December, 1930. | Number served. | Number complied with up to 31st December, 1930. |
| 3,438 | 2,688 | 898 | 548 |
REPAIRS EFFECTED.
The following works were carried out and repairs effected as a result of the action of the
sanitary inspectors: —
TABLE 9.
| DRAINAGE. | Drains cleared | 202 |
| Drains repaired | 276 | |
| Drains relaid | 366 | |
| Soil and ventilation pipes repaired | 78 | |
| Soil and ventilation pipes renewed | 18 | |
| New Soil and ventilation pipes provided | 98 | |
| Rain water gutters and pipes repaired and renewed | 467 | |
| Drains sealed off | 13 | |
| Disused drains excavated | 1 | |
| Fresh Air inlet | 62 | |
| WATER CLOSETS. | Traps cleansed, repaired, etc. | 420 |
| Pans renewed | 602 | |
| Seats repaired or renewed | 406 | |
| Flushing cisterns repaired | 351 | |
| Flushing cisterns renewed | 14 | |
| Additional W.C. accommodation provided | 15 | |
| Lobbies provided to W.C. apartments | 3 | |
| Fastenings provided to doors, and doors repaired | 123 | |
| W.C. apartments ventilated | 55 | |
| SINKS, BATHS AND LAVATORY BASINS. | Sinks provided | 80 |
| Sinks renewed | 336 | |
| Sinks repaired | 40 | |
| Sink waste pipes trapped | 431 | |
| New sink waste pipes provided | 186 | |
| Sink and Bath wastes repaired | 156 | |
| New baths fitted | 66 | |
| New lavatory basins fitted | 100 | |
| New bath and lavatory wastes fitted | 36 | |
| Baths cleansed | 3 | |
| WATER SUPPLY. | Drinking water cisterns cleansed, etc., | 129 |
| Water supplied from mains | 16 | |
| Occupied house provided with a sufficient supply | 25 | |
| Water supply pipes and fittings repaired | 65 | |
| Water supply provided to separate floors | 25 |