Hints from the Health Department. Leaflet from the archive of the Society of Medical Officers of Health. Credit: Wellcome Collection, London
[Report of the Medical Officer of Health for Tottenham]
This page requires JavaScript
Average Results of the Chemical and Bacteriological Examinations of the Water Supplied to the Borough of Tottenham
for the Year 195a
Parts per Million (Unless otherwise stated)
Description of the Sample | No, of Samples | Ammoniacal Nitrogen | Albuminoid Nitrogen | Oxidised Nitrogen | Chlorides as CI. | Oxygen, abs. from Permanganate 3hrs at 80°F | Turbidity in Terms of Silica | Colour. m.m. brown 2ft. Tube Burgess's Tintometer | Hardness (Total) | Hardness (Non- carbonate) | PH. Value | Phosphate as P.O. 111 4 | Silica as si0 2 | Conductivity | |||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nitrite | Nitrate | ||||||||||||||||
New River water filtered at Hornsey works | 250 | 0.033 | 0.074 | 7. 4 | 40. 8 | 0.80 | 0.1 | 9 | 308 | 80 | 7. 7 | 0. 51 | 15 | 550 | |||
New River water filtered at Stoke New- Winston works | 250 | 0.041 | 0.075 | 6. 8 | 40.8 | 0.78 | 0.1 | 9 | 305 | 80 | 7.8 | 0.48 | 13 | 550 | |||
River Thames water filtered at Walton works | 249 | 0.021 | 0.088 | 4. 5 | 23.0 | 1.35 | 0.2 | 16 | 258 | 63 | 7.8 | 0.33 | 13 | 450 | |||
Bacteriological Results | |||||||||||||||||
Description of Sample | No. of Samples | No. of microbes per ml. Colonies counted on agar after 20 24 hrs. at 37°C. | Bact. coli Test | ||||||||||||||
percentage of samples negative to Bact. coli in 100 ml. | Bact. coli per 100 ml. | ||||||||||||||||
New River water filtered at Hornsey works | 256 | 36.0 | 100.0 | Nil | |||||||||||||
New River water filtered at Stoke Newington works | 256 | 35.6 | 99.6 | 0.012 | |||||||||||||
River Thames water filtered at Walton works | 255 | 22.7 | 99.6 | 0.004 |