SANITARY CIRCUMSTANCES OF THE AREA
WATER
Full particulars of the origin and the purification of water supplies
to this district were set out in the Annual Report for 1954.
So that the Authority may comply with the obligation imposed by
Section 111 of the Public Health Act, 1936 to ascertain the wholesomeness
of the water supplies in the district, samples are submitted periodically
for chemical and bacteriological analysis. In addition reports are
received each week from the Chief Chemist of the Colne Valley Water
Company on the results of the examination of samples collected at
different premises in the district.
The following is a summary of a typical chemical analysis (Chemical
Results in Parts per Million).
Appearance: Bright with a few mineral particles
Colour: nil. Turbidity: less than 3. Odour: nil.
pH: 7.3. Free Carbon Dioxide: 18
Electric conductivity: 690. Total Solids: 480.
Chlorine present as chloride: 45. Alkalinity as Calcium Carbonate: 255.
Hardness: Total 290. Carbonate 255, Non-carbonate 35.
Nitrate Nitrogen: 4.0. Nitrate Nitrogen: less than 0.01.
Ammoniacal Nitrogen: 0.021. Oxygen absorbed: 0.35.
Albuminoid Nitrogen: 0.000. Residual Chlorine: absent.
Metals: Iron 0.03, other metals absent.
"This sample is practically clear and bright in appearance, neutral in reaction
and free from metals apart from a negligible trace of iron. The water is hard
in character but its hardness and its content of mineral and saline constituents
in solution are not excessive. Its organic quality is of a high standard.
These results are indicative of a water which is pure and wholesome in
character and suitable for drinking and domestic purposes."
The following, a copy of a bacteriological examination of a sample
submitted for analysis in August, is typical of other reports:
Plate count. Yeastrel agar 2 days anaerotically: 1 per ml.
Probable number of coliform bacilli: MacCoukey 2 days 37°C: not found.
Probable number of faecal coli: not found.
A local resident drew attention to the possibility of copper being
present in water as drawn off in the house. Suspicion arose from the
green discolouration of the fur inside a new enamel kettle. Analysis of the
fur showed the presence of copper. The water was supplied through into
the house in copper pipes. Although there was no apprehension that
even though copper were taken up by the water there was any risk to
health especially as copper as contrasted with lead is not cumulative
poison, the opinion of the chief chemist of the Colne Valley Water
Company was sought. The company carried out very thorough tests
from which it was found that although the water supplied by the company
is free from copper, traces of copper were present as drawn off in this
house. On heating the water, the copper precipitated. When this
occurs in an aluminium kettle, electrolytic action takes place which in
time might lead to perforation of the kettle. When copper pipes are
used then it is advisable that kettles of copper, or enamel and not of
aluminium be used. A reduction in the action of the copper can be