METROPOLITAN WATER BOARD - WATER EXAMINATION DEPARTMENT AVERAGE RESULTS OF THE CHEMICAL EXAMINATION OF WATER APPLIED TO THE CORPORATION OF LONDON FOR 1971 Milligrammes per litre (unless otherwise stated)

Description of the SamplesNumber of SamplesAmmoniacal NitrogenAlbuminoid NitrogenNitrate NitrogenOxygen abs. from KMn04 4 hrs. at 27°C.B.O.D. 5 days at 20°C.Hardness (total) CaC03Hardness (non-carbonate) CaC03Magnesium as MgSodium as NaPotassium as KChloride as CIPhosphate as P04Silicate as Si02Sulphate as S04Natural Fluoride as FSurface-active material as Man ox o I OTTurbidity unitsColour (Burgess units)PH valueElectrical Conductivity (micromhos)
(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)
Stoke Newington520.0270.0646.30.61-30485530.35.2421.99620.200.020.197.8630
River Thames derived3640.0290.0846.11.04-28190523.55.1342.310640.150.020.1137.8580

BACTERIOLOGICAL RESULTS - YEARLY AVERAGES, 1971. WATER SUPPLIED TO THE CORPORATION OF LONDON

Sources of SupplyBEFORE TREATMENTAFTER TREATMENT
Agar plate count per ml.Coliform countEscherichia coli countAgar plate count per ml.ColiformE. coli count
Number of Samples20-24 hours at 37°C.3 days at 22°C.Per cent samples negative in 100 ml.Count per 100 ml.Per cent samples negative in 100 ml.Count per 100 ml.Number of Samples20-24 hours at 37°C.3 days at 22°C.Per cent samples negative in 100 ml.Per cent samples negative in 100 ml.
Stoke Newington75241.352.139.071.541.025823.2100.0100.0
River Thames — derived8,15453.940.3712.254.915.13,9018.399.5199.97